Skip to main content

Table 2 Perioperative and Postoperative Characteristics of the Study Population

From: Clinical outcomes after transcatheter aortic valve replacement in cancer survivors treated with ionizing radiation

Variablea

All subjects (n = 610)

Non- XRT Group (n = 535)

C-XRT Group (n = 75)

P value

TAVR Access/duration

 Femoral Access

535 (87.7)

472 (88.22)

63 (84.0)

0.34

 Median Procedure duration (hrs:mins/ interquartile)

2:17 (1:40–2:48)

2:16 (1:04–3:28)

2:23 (1:29–3:07)

0.38

Valve types

 Edwards Sapien

500 (81.9)

438 (81.87)

62 (82.67)

0.86

 Core Valve

110 (18.1)

97 (18.13)

13 (17.33)

Post-procedure parameters

 Mod-severe Paravalvular leak

9 (1.48)

8 (1.5)

1 (1.35)

0.91

 Post-procedure Hb

9.66 ± 1.75

9.73 ± 1.76

9.12 ± 1.6

0.004

 Post-procedure Creatinine

1.52 ± 1.34

1.50 ± 1.28

1.64 ± 1.7

0.41

 Creatinine at discharge

1.3 ± 1.1

1.3 ± 1.1

1.28 ± 1.1

0.73

 Post TAVR LVEF

55.05 ± 12.4

54.72 ± 12.74

57.4 ± 9.8

0.081

 Post TAVR AVA, cm2

1.90 ± 0.49

1.91 ± 0.49

1.87 ± 0.5

0.53

 Post TAVR Peak gradient, mm Hg

7.93 ± 4.64

7.94 ± 4.59

7.87 ± 5

0.9

 Post TAVR mean gradient, mm Hg

3.62 ± 2.28

3.62 ± 2.23

3.64 ± 2.6

0.94

  1. C-XRT indicates mediastinal radiation exposure
  2. Hb hemoglobin, LVEF left ventricular ejection fraction, AVA aortic valve area
  3. aValues are expressed as number (percentage) or mean ± SD